Anchor bolts and bolt forces
according to AD 2000 Merkblatt S 3/0
Attention!
This calculation is only a simplified estimation, and does not replace a detailed design calculation.
Input data
Bolt circle diameter
mm
Number of bolts
Bolt type/size
M8 full
M10 necked-down
M10 full
M12 necked-down
M12 full
M16 necked-down
M16 full
M20 necked-down
M20 full
M22 necked-down
M22 full
M24 necked-down
M24 full
M27 necked-down
M27 full
M30 necked-down
M30 full
M33 necked-down
M33 full
M36 necked-down
M36 full
M39 necked-down
M39 full
M42 necked-down
M42 full
M45 necked-down
M45 full
M48 necked-down
M48 full
M52 necked-down
M52 full
M56 necked-down
M56 full
M64 necked-down
M64 full
Bolt material
St 4.6
St 5.6
St 5.8
St 8.8
St 10.9
St 12.9
Load case
name
Load case
type
Design
temperature
[°C]
Min. weight
force
[kN]
Bending
moments
[kN·m]
Calculate
Results
Load case
name
Anchorage
necessary
Max.
bolt force
[kN]
Max.
efficiency
[%]
www.pvp-software.de
© Lau Engineering Solutions GmbH