Print...
Copy data to clipboard:
  Click - as simple text
  Ctrl+Click - compressed
  Shift+Click - as link
Paste data from clipboard
Example calculation

Dimensions of bends fabricated from specified tubes

with inside and outside corrosion and fabrication tolerance considered

Input data

 Nominal outside diameter mm
 Bend radius mm
 Nominal wall thickness mm
 Manufacturing tolerance %
 Corrosion inside mm
 Corrosion outside mm
 
 
 

Results

 Bending factor extrados  
 Bending factor intrados  
 End-of-life extrados thickness mm
 End-of-life intrados thickness mm

www.pvp-software.de
© Lau Engineering Solutions GmbH